CES 2250P

Diesel Generator Set

- Meets Emission Standards

- Impressive performance across various application

CES 2250P Model Details

Key features

Guarranteed uptime for Critical performance - long usge period between mainteance.

Quick and Easy service results in more productive hours.

Unit Fuel injectors ensures ultra fine fuel atomisation and controller rapid combustion over a varied range of load.

Commonality of components for 4000 series range (750 kVA- 2250 kVA).

Designed for low cost of owenership, simple maintenace and lower downtime over a range of load.

Prime Power
Output
Engine
Manufacturer
Engine
Model
Gross Engine
Power
Engine Cooling
System
No.of Cylinder
and Position
Displacement Aspiration
2250 kVA /
1860 kW
Perkins 4016-61TRG3 1975 kWm Liquid Cooled 16, 60◦ Vee 61.1 Litre Quad Turbocharged
air to water charge cooled
Bore x Stroke Recommended
Fuel
Combustion
System
Compression
Ratio
Total Lubricating
Capacity
Total Coolant
Capacity
Specific Fuel
Consumption (g/ kWh)
 
160 x 190 mm HSD Direct Injection 13:01 237.2 Litre 385 Litre 100%Load : 205
75 % Load : 200
50% Load : 204
 
Alternator
Rated Power
Rated
Voltage (L-L)
Frequency Rated
Speed
Rated
Current
Power
Factor
Poles Phase
2250 kVA 415 V 50 Hz 1500 rpm 3130.2 amp 0.8 (lagging) 4 3
Insulation Class Temperature
Rise Limit
Protection Voltage
Regulation
Over Load
Capability
Excitation
System
   
Class H Class H IP 23 ± 1% 10% for 1 hour in
every 12 hours
operation
Brushless    
Prime Power Output 2250 kVA/ 1860 kW
Engine Manufacturer Perkins
Engine Model 4016-61TRG3
Gross Engine Power 1975 kWm
Engine Cooling System Liquid Cooled
No.of Cylinder and Position 16, 60◦ Vee
Displacement 61.1 Litre
Aspiration Quad Turbocharged air to air charge cooled
Bore x Stroke 160 x 190 mm
Recommended Fuel HSD
Combustion System Direct Injection
Compression Ratio 13:01
Total Lubricating Capacity 237.2 Litre
Total Coolant Capacity 385 Litre
Specific Fuel Consumption (g/kWh) 100% Load : 205
75% Load : 200
50% Load : 204
Alternator Rated Power 2250 kVA
Rated Voltage (L-L) 415 V
Frequency 50 Hz
Rated Speed 1500 rpm
Rated Current 3130.2 amp
Power Factor 0.8 (lagging)
Poles 4
Phase 3
Insulation Class Class H
Temperature Rise Limit Class H
Protection IP 23
Voltage Regulation ± 1%
Over Load Capability 10% for 1 hour in every 12 hours operation
Excitation System Brushless

Request a
Quote for
CES 2250P

Request A Quote for
CES 2250P DG Set

Note: The information shared by you is for our internal processing purpose. This information will not be shared by us with any third party.