50 Hz DG
MODELS

Product range to cater
Global application

Localised after market solution and meeting specific emission standards.

50 Hz Diesel Generator Models
for International Market

Key features

Fitted with integral six-sided acoustic enclosure..

Designed and tested for ideal performance..

Engines are designed for exceptional power to weight ratio, high reliability and lowest cost of ownership..

Equipped with full electronic control for advanced performance monitoring..

Mechanically actuated electronically controlled unit fuel injectors to achieve excellent fuel efficiency.

Fuel Optimised Models

Generating Set Power Selector

50 Hz Net Engine Output Typical Generator Set Output
Litres Model Baseload Prime Standby Baseload Prime Standby 1500/1800
rev/min
switchable
kWm kWm kWm
kWe kVa
kWe kVa
kWe kVa
1500 rpm (9 kVA to 2500 kVA)
1.1 403A-11G1 - 8 9
- -
7 9
8 10
-
1.5 403A-15G1 - 12 13
- -
10 13
12 15
-
403A-15G2 - 14 15
- -
12 15
13 16
 
2.2 404A-22G1 - 18 20
- -
16 20
18 22
-
3.3 1103A-33G - 28 30
- -
24 30
26 33
1103C-33TG2 - 41 46
- -
37 46
41 51
-
1103A-33TG1 - 41 46
- -
36 45
40 50
1103A-33TG2 - 54 59
- -
48 60
53 66
4.4 1104C-44G1 - 39 43
- -
35 44
39 48
-
1104C-44TG2 - 54 59
- -
48 60
53 67
 
1104A-44TG1 - 58 64
- -
52 65
57 72
1104A-44TG2 - 72 79
- -
64 80
70 88
1104C-44TAG1 - 72 79
- -
64 80
71 89
 
1104C-44TAG2 - 90 100
- -
81 101
90 112
 
7.0 1106A-70TG1 - 118 131
- -
108 135
120 150
-
1106A-70TAG2 - 131 144
- -
120 150
132 165
 
1106A-70TAG3 - 158 175
- -
144 180
160 200
 
1106A-70TAG4 - 174 191
- -
160 200
176 220
-
1206A-E70TTAG1 - 177 195
- -
160 200
180 225
 
1206A-E70TTAG2 - 195 217
- -
184 230
200 250
 
1206A-E70TTAG3 - 217 238
- -
200 250
220 275
 
8.8 1506A-E88TAG4 - 244 267
- -
220 275
240 300
 
1506A-E88TAG5 - 268 293
- -
246 308
270 337
 
9.3 1706A-E93TAG1 - 267 295
- -
246 307
271 339
 
1706A-E93TAG2 - 302 334
- -
278 348
307 384
 
12.5 2206A-E13TAG2 - 305 349
- -
280 350
320 400
 
2206A-E13TAG5 - 305 349
- -
280 350
320 400
 
2206C-E13TAG2 - 305 349
- -
280 350
320 400
 
2206A-E13TAG3 - 349 392
- -
320 400
360 450
 
2206C-E13TAG3 - 349 392
- -
320 400
360 450
 
2206C-E13TAG3 - 349 392
- -
320 400
360 450
 
15.2 2506A-E15TAG1 - 396 434
- -
364 455
400 500
 
2506C-E15TAG1 - 396 435
- -
364 455
400 500
 
2506A-E15TAG2 - 435 478
- -
400 500
440 550
 
2506C-E15TAG2 - 435 478
- -
400 500
440 550
 
18.1 2806C-E18TAG1A - 514 565
- -
473 591
520 650
 
2806A-E18TAG1A - 522 574
- -
480 600
528 660
 
2806A-E18TAG2 - 565 609
- -
520 650
560 700
 
2806A-E18TTAG4 - 595 609
- -
565 706
624 780
 
2806A-E18TTAG5 - 648 716
- -
616 770
680 850
 
23.0 4006-23TAG2A 505 632 695
476 595
597 746
656 820
 
4006-23TAG3A 536 675 756
509 637
641 802
718 898
-
30.0 4008-30TAG1 632 758 842
600 750
720 900
800 1000
-
4008TAG1A 606 767 844
576 720
728 911
802 1002
-
4008-30TAG2 674 851 947
640 800
808 1010
900 1125
-
4008TAG2A 681 861 947
647 809
818 1022
900 1125
-
4008-30TAG3 800 947 1055
760 950
900 1125
1000 1250
-
46.0 4012-46TAG0A 842 1053 1158
800 1000
1000 1250
1100 1375
-
4012-46TWG2A 833 1055 1166
791 989
1002 1253
1108 1385
 
4012-46TAG1A 909 1148 1263
864 1080
1091 1364
1200 1500
-
4012-46TWG3A 909 1149 1263
864 1079
1092 1364
1200 1500
-
4012-46TWG4A - 1254 1342
- -
1200 1500
1280 1600
-
4012-46TAG2A 1005 1267 1395
955 1194
1204 1505
1325 1656
 
4012-46TAG3A 1200 1440 1583
1140 1425
1368 1710
1504 1880
-
61.0 4016TAG1A 1219 1537 1690
1170 1463
1476 1844
1622 2028
-
4016-61TRG1 1179 1558 1684
1120 1400
1480 1850
1600 2000
-
4016-61TRG2 1347 1684 1895
1280 1600
1600 2000
1800 2250
-
4016TAG2A 1362 1715 1886
1307 1634
1646 2058
1811 2263
-
4016-61TRG3 1500 1875 2083
1440 1800
1800 2250
2000 2500
-

Switchable engines must be requested at point of order, please consult with your local Perkins representative
Can be switched between 1500 and 1800 rpm

Notes:

All ratings are rounded to the nearest whole number and are for guidance only. Please refer to the technical data or specification sheet for accurate powers.

Electrical output is based on assumed alternator efficiency and is for guidance only.

kVA figures are calculated using a typical power factor of 0.8.

Perkins conditions of sale apply.

All ratings data based on operation under ISO 8528-1, ISO 3046, DIN6271 conditions using typical fan sizes and drive ratios. Performance tolerance quoted by Perkins is ± 5%.

Baseload Power = Power available for continuous full load operation. An overload of 10% permitted for one hour in every twelve hours of operation. Please Note: No overload is permitted on 4000 Series.

Prime Power = Power available at variable load in lieu of main power network (please refer to the engine Technical Data Sheets for engine load factors). An overload of 10% permitted for one hour in every twelve hours of operation.

Standby Power = Power available at a variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.

Request a
Quote for
50 Hz

Request A Quote for
International 50 Hz DG MODELS

Note: The information shared by you is for our internal processing purpose. This information will not be shared by us with any third party.